5930-01-502-8779
FSC | NIIN | NAME |
---|---|---|
5930 | 015028779 | SWITCH,PRESSURE-THERMOSTATIC |
Request for Quote
Identification
PMIC | ADPE CODE |
CRITL CODE |
DEMIL CODE |
DEMIL INTG |
NIIN ASGMT |
ESD | HMIC | ENAC | SCHEDULE B | INC |
---|---|---|---|---|---|---|---|---|---|---|
A | 0 | X | A | 1 | 22-NOV-2002 | A | P | 8536509065 | 13383 |
5930-01-502-8779 Master Cross Reference Data
Mfr. Part Number | Cage - Company Name | ISC | RNVC | RNCC | HCC | MSDS | SADC | DA |
---|---|---|---|---|---|---|---|---|
1173T0797-03 | 98087 - ITT AEROSPACE CONTROLS LLC DBA ITT AEROSPACE CONTROLS UNIT S | 2 | 3 | E | ||||
GS839KN1 | 26512 - NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN CORPORATION DIV MISSION SYSTEMS | 2 | 7 | 2 |
5930-01-502-8779 Technical Characteristics
MRC | Requirements Statement | Reply |
---|---|---|
ABHP | OVERALL LENGTH | 3.900 INCHES MINIMUM AND 4.100 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | CEC PROVISION,HAWKEYE E-2C AIRCRAFT |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
ASDB | WIDTH ACROSS FLATS | 0.660 INCHES MINIMUM AND 0.720 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | PLUG-IN TERMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 335.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 315.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL SINGLE VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | STYLE DESIGNATOR | CYLINDRICAL |